- What is an AIA G704?
- Who prepares the certificate of substantial completion?
- What is a G706 form?
- What is a G702 form?
- How do you calculate substantial completion?
- Is punch list before or after substantial completion?
- What percentage is substantial completion?
- What is a G704 AIA Document?
- What is the AIA Document for substantial completion?
- What is AIA g715 used for?
What is an AIA G704?
AIA Document G704®–2017 is a standard form for recording the date of substantial completion of the work or a designated portion thereof. The contractor prepares a list of items to be completed or corrected following substantial completion, and the architect verifies and amends this list.
Who prepares the certificate of substantial completion?
Certificate of Substantial Completion means a certificate prepared by the Design/Builder and forwarded to the Owner stating that the Project is sufficiently complete so it can be used for its intended purpose.
What is a letter of substantial completion?
The date of substantial completion of the work is the date certified by the Owner when construction is sufficiently complete, in accordance with the contract documents, so the Owner can occupy or utilize the work for which it is intended, as expressed by the contract documents.
What is a G706 form?
AIA Document G706 is intended for use when the Contractor is required to provide a sworn statement verifying that debts and claims have been settled, except for those listed by the Contractor under “EXCEPTIONS” in the document. AIA Document G706 is typically executed as a condition of final payment.
What is a G702 form?
Form G702 (Application and Certificate for Payment) is used by subcontractors throughout America to make the procedure for receiving payments for work performed regulated and convenient for all parties to the process. Such forms indicate the amount of payment paid for the work done for a certain period.
What is substantial completion certificate?
A certificate of substantial completion includes a list of items remaining to be corrected or completed, as well as the timeline allotted for those items. A certificate of occupancy is issued by a local building inspector, and establishes that the building is safe to occupy and utilize.
How do you calculate substantial completion?
Substantial Completion
- Completed in accordance with plans and specifications previously approved by the landlord and tenant.
- Completed in compliance with all applicable laws.
- Reviewed and approved by any local regulating authorities that have issued permits for the construction of the tenant improvements.
Is punch list before or after substantial completion?
A punch list provides the contractor, architect and owner an opportunity to identify remaining work at substantial completion. It is usually provided for by contract. It is the final step in the collaborative process of assuring that the project is delivered in accordance with the design intent.
What is Consent of Surety to release retainage?
This is a standard form for use when a surety company is involved and the owner/contractor agreement contains a clause whereby retainage is reduced during the course of the construction project.
What percentage is substantial completion?
Final Completion. Substantial completion and final completion are the two final phases of a project. Substantial completion refers to when the building can be used for its intended purpose. Final completion occurs when the project is 100% complete and requires no additional work.
What is a G704 AIA Document?
Synopsis. AIA Document G704–2017 is a standard form for recording the date of substantial completion of the work or a designated portion thereof. The contractor prepares a list of items to be completed or corrected following substantial completion, and the architect verifies and amends this list.
What is the difference between AIA g612 and g701?
G612-2017, Owner’s Instructions to the Architect Part B AIA Document G612™-2017 is a questionnaire, drafted to elicit information from the owner regarding the nature of the construction contract. AIA Document G701™-2017 is used for implementing changes in the work agreed to by the owner, contractor, and architect.
What is the AIA Document for substantial completion?
Document G704TM– 2000 Certificate of Substantial Completion AIA Document G704™ – 2000. Copyright © 1963, 1978, 1992 and 2000 by The American Institute of Architects. All rights reserved. WARNING: This AIA®Document is protected by U.S. Copyright Law and International Treaties.
What is AIA g715 used for?
AIA Document G715™–2017 is intended for use in adopting ACORD Form 25 to certify contractor insurance coverages required under standard form AIA agreements. G716–2004, Request for Information (RFI) This form is used to formally request further information from a party during construction.